Physical structure | ||
---|---|---|
Materials | Dimensions | |
Center conductor | Silver-plated copper (SPC) | 0.66+/-0.0250mm (0.0280+/-0.0010 inch) |
Dielectric | PEEK | 2.98+/-0.1000mm (0.117+/-0.0039 inch) |
Outer conductor | Oxygen-free copper | 3.58+/-0.1000mm (0.141+/-0.0254 inch) |
Electrical properties* | |
---|---|
Characteristic impedance | 50.0+/-2.5ohms |
Voltage withstanding @60Hz | 2500VRMS |
Corona extinction voltage @60Hz | 950VRMS |
Maximum operating frequency | 30GHz |
Average capacitance | 121.70pF/m |
FRQ. | Attenuation Loss | Power Rating | |
Attenuation loss @20゚C & Power rating @40゚C |
0.5GHz | 0.60dB/m | – |
1.0GHz | 1.00dB/m | – | |
5.0GHz | 3.60dB/m | – | |
10.0GHz | 6.50dB/m | – | |
20.0GHz | 12.30dB/m | – |
Mechanical properties | |
---|---|
Eccentricity | Less than 7% |
Minimum inside bend radius | 12.0mm |
Operating temperature | -40℃ to +200℃ |
Average weight | 47.00g/m |
Standard length | 1 or 2m |
* Electrical properties are reference data/value by measurement and calculation.